It is imperative to engage a testing company with expertise in regulatory compliance and contamination control to ensure the safety and efficacy of your medical devices and 清洁 and disinfection processes. im体育APP reusable medical device reprocessing validation services help you ensure the safety of your staff and your patients.
Reusable 医疗设备 Tests (GLP Compliant)
再加工周期
Every reusable medical device must be reprocessed before reuse to minimize risk of contamination. A standard reprocessing cycle includes 清洁 and either sterilization or disinfection. These reprocessing Instructions for Use (IFU) must undergo validation to ensure they effectively remove various contaminants. Whether validating existing Instructions for Use (IFU) or helping to create new IFU with our guidance, our experts will develop a separate testing protocol for each processing category applicable.
Multiple standards discuss the validation and test methods for reprocessing reusable medical devices, 例如AAMI tir12, AAMI TIR 30 (draft ST98), ANSI / AAMI ST58, ANSI / AAMI ST79, ISO 17664, and the FDA guidance document “Reprocessing 医疗设备 in Health Care Settings: Validation Methods and Labeling”.
Cleaning a reusable medical device prior to disinfection or sterilization is critical to ensure no soil remains that could limit the ability of the disinfection or sterilization process to kill organisms. A standard 清洁 validation consists of soiling devices with a representative artificial soil and 清洁 using the worst-case 清洁 methods. A number of controls are performed alongside the test replicates to ensure that the test methodology used is appropriate for your device.
Disinfection or sterilization validation
Disinfection validations for reusable medical devices are performed to ensure the disinfection method chosen for the device effectively kills representative organisms. A device that cannot undergo sterilization will undergo either low-, 中间,, or high-level disinfection depending on the criticality of the device and the potential exposure to pathogens. Devices are inoculated with representative organism(s), depending on the level of disinfection, and disinfected using a worst-case disinfection procedure. Surviving organisms are recovered using a suitable neutralizer and quantified to determine the efficacy of the disinfection IFU.
Sterilization validation studies for reusable medical devices ensure that the sterilization parameters chosen for your device adequately kill organisms. These are paired with dry time studies to ensure that the dry time post-steam sterilization is long enough to prevent residual moisture that could encourage microbial growth.
im体育APP优势
In cases where reprocessing parameters are not ready for validation, im体育APPs experts have the experience and knowledge to test parameters in a non-regulatory, R&D setting and finalize reprocessing instructions ready for the validation phase. Our team serves on a number of standards committees and can provide guidance in determining worst-case soiling, 清洁, and disinfection procedures to ensure your validation is sufficiently robust.
If you'd like to learn more about our medical device reprocessing validation services, im体育APP 今天.
了解更多
Reusable 医疗设备 Life Cycle Validation
Our medical device experts evaluate the environmental impact on the identification markings and function of reusable medical instruments after repeated autoclave sterilization cycles.
医疗设备 Regulatory Services
im体育APP’s regulatory advisors have 30 years of domestic and international regulatory consulting experience, specializing in handling the most complex challenges and partnering with you on the path to submission.
医疗仪器测试
As a comprehensive testing partner, you’ll enjoy the benefit of a single supplier source for all of your testing needs, from mechanical testing and environmental simulation to EMC and wireless device testing.